Home Server Land
  • Hardware
    • Devices
    • Network Attached Storage
    • Networking
    • Home Server
  • Software
  • Reviews
  • Cool
  • Store

Add-in: Home Server SMART v2 Released

By: Alexander Kent|September 3, 20112 Comments
Add-in: Home Server SMART v2 Released

Dojo North Software, makers of the popular Home Server SMART add-in for Windows Home Server v1 got in touch to announce the immediate availability of Home Server SMART version 2.

Home Server SMART

The new version includes a number of new features, most notable being automatic continuous monitoring and alerting as well as the much requested “USB disk support”.

Home Server SMART

Matthew Sawyer: “Home Server SMART v2 for WHS v1 Released!”

After many months in beta, I have finally released version 2 of Home Server SMART! HSS v2.0.8.25 includes a number of features many folks have been asking for, including automatic, continuous disk monitoring and support for USB disks. While these features were available in the public beta, many folks don’t participate in a beta and so for many these features will be brand new.

If a disk’s health starts to degrade, HSS raises an alert within WHS, either Warning or Critical (depending on severity), which results in the standard WHS tooltip popping up on each connected computer. For those folks who have installed Alex Kuretz’s Remote Notification add-in (available at www.remotenotification.com), you can be notified of degraded or failing disks even if you are away from your home.

The UI received quite a bit of work, including new visual health indicators in the disk selector. These provide the user with an “at a glance” view of the health of each disk, without needing to visit each disk individually. Descriptive help text is now provided for every SMART attribute on each disk. Simply double-click on any attribute, whether or not it’s healthy, and you’ll get a detailed explanation of the attribute, and also an indicator of whether or not that attribute is in an unhealthy state for that particular disk.

Another new feature is the ability to ignore certain problems within HSS itself. If you have a disk with a low number of bad sectors, for instance, and the problem isn’t getting any worse, you can click an Ignore Problem button while the attribute in question is highlighted. HSS will stop generating an alert for this item—as long as it doesn’t get any worse. If the problem worsens, HSS will let you know. Not every problem can be ignored however. If a SMART threshold is violated, per the specification this is a catastrophic failure condition and cannot be ignored.

The last new feature to be implemented was an update checker. If you go into Home Server SMART’s Settings, under the Resources tab, click the Check button to see if an update is available.

There were plenty of bug fixes as well. The pesky null reference exception and WMI “not supported” messages should finally be laid to rest. Some Silicon Image (SiI) controllers weren’t displaying any data, but are now. Some users encountered console crashes when performing a manual refresh. There were also a number of bugs that popped up during the beta that were resolved as the beta progressed.

Numerous changes were also implemented. Several things were cosmetic, like button icon changes. Others were more significant, like changing how data was stored and read from the Registry to improve UI response times, as well as consolidating modules to cut down on the add-in’s footprint on the server and in terms of memory consumption.

Known Issues

There is a major known issue – some folks with SiI controllers are not getting any SMART data in any version of Home Server SMART. I don’t know if this is the result of a change in drivers, or user configuration of drives. Because I am not an “SiI partner,” they won’t release their driver API to me so I don’t have any realistic way to research it further.

Availability, Download & Pricing

Please visit the Home Server SMART page to download the add-in. The help file, provided with the add-in, is available as a standalone download. This help file includes the full release notes including all new features, changes, bug fixes and known issues.

Home Server SMART Homepage: http://www.dojonorthsoftware.net/Freebies/HomeServerSMART.aspx

Skip the Details – NOT SO FAST COWBOY!!! (Addendum 9/6/2011)

Microsoft Visual C++ 2008 Runtime MUST be installed or HSS may not work correctly (no USB support, P/Invoke calls fail).  Here’s the link to the Visual C++ 2008 Runtime:  http://www.microsoft.com/download/en/details.aspx?id=5582

Direct Download for HSS v2: http://www.dojonorthsoftware.net/Freebies/dl/HomeServerSMART_WHSv1_v2.0.8.25.zip

Direct Download for HSS v2 Help: http://www.dojonorthsoftware.net/Freebies/dl/HomeServerSMART_v2.chm

For WHS 2011 users, there is good news! I got another server this week, an EX487, and have WHS 2011 installed. Now that v2 of HSS is out for WHS v1, I can start working on HSS for WHS 2011. Please check http://www.dojonorthsoftware.net/Freebies/HomeServerSMART2011.aspx for more details.

Home Server SMART is, and always will be, 100% free for you to download and use. There are no ads, no spyware, no annoying pop-ups and no prompts asking for you to register. The software will be fully operational and full featured all the time. Home Server SMART does, however, represent the result of hundreds of hours of work…researching SMART, buying new hardware, coding the application, debugging, fixing bugs, following up with beta testers, more testing, etc. If you like this add-in and find it useful, and would like to show a small token of appreciation, please make a donation at the link below. This is not required, but is certainly appreciated.

https://www.paypal.com/cgi-bin/webscr?cmd=_s-xclick&hosted_button_id=11344152

More: Discussion | Home Server SMART Homepage

2 Responses to Add-in: Home Server SMART v2 Released

  • Matthew Sawyer September 6, 2011

    This was overlooked as a prerequisite. Please make sure you have installed the Microsoft Visual C++ 2008 Runtime on your WHS. Without this runtime, or a later version of it, Home Server SMART may fail to yield data for internal disks, and WILL fail to yield data for USB disks.

    You can download the runtime directly from Microsoft. It must be installed via a Remote Desktop connection to your home server. Download:http://www.microsoft.com/download/en/details.aspx?id=5582

    Reply
  • John Schumann December 20, 2011

    HSS V2 for WHS 2011 is posted (30 Nov) ….nice implementation!

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Popular Posts

  • Giveaway: WinX DVD Ripper Software
    Giveaway: WinX DVD Ripper Software January 31, 2011
  • Apple Video Converter Factory Pro 3.0 Giveaway!
    Apple Video Converter Factory Pro 3.0 Giveaway! April 19, 2011
  • First Look: Add-in Central
    First Look: Add-in Central December 12, 2009
  • Grid Junction 2.0 for WHS 2011 and SBS Essentials 2011 Discontinued
    Grid Junction 2.0 for WHS 2011 and SBS Essentials 2011 Discontinued January 29, 2012
  • Folding@home on Windows Home Server
    Folding@home on Windows Home Server June 9, 2010

Recent Posts

  • Thermostat of the Future… NEST v2 is Here Today!
  • Synology DiskStation DS213+ Hardware Review
  • Neato meet Benji, Benji meet XV-21!!!
  • Grid Junction 2.0 for WHS 2011 and SBS Essentials 2011 Discontinued
  • Tworb with Us

Recent Comments

  • Shardesh on How to: Repair your Corrupted SD Card
  • DirtyFinger on Synology DiskStation DS213+ Hardware Review
  • Slinky on How to: Repair your Corrupted SD Card
  • Danny on Hands-on: HP ProLiant MicroServer Review
  • Danny on Hands-on: HP ProLiant MicroServer Review

Popular Posts

  • Giveaway: WinX DVD Ripper Software January 31, 2011
  • Apple Video Converter Factory Pro 3.0 Giveaway! April 19, 2011
  • First Look: Add-in Central December 12, 2009
  • Grid Junction 2.0 for WHS 2011 and SBS Essentials 2011 Discontinued January 29, 2012
  • Folding@home on Windows Home Server June 9, 2010

Recent Comments

  • Shardesh on How to: Repair your Corrupted SD Card
  • DirtyFinger on Synology DiskStation DS213+ Hardware Review
  • Slinky on How to: Repair your Corrupted SD Card
  • Danny on Hands-on: HP ProLiant MicroServer Review
  • Danny on Hands-on: HP ProLiant MicroServer Review

Search HSL

We’re Social

Follow Us on FacebookFollow Us on TwitterFollow Us on YouTube
Copyright ©2009-2013. All Rights Reserved.
  • About
  • Contact
  • Terms
  • Privacy